{"id":13746,"date":"2022-05-29T22:29:28","date_gmt":"2022-05-29T22:29:28","guid":{"rendered":"https:\/\/aquaconsult.ee\/?page_id=13746"},"modified":"2022-07-01T11:47:46","modified_gmt":"2022-07-01T11:47:46","slug":"kalev-kommivabrik","status":"publish","type":"page","link":"https:\/\/aquaconsult.ee\/en\/kalev-kommivabrik\/","title":{"rendered":"kalev-kommivabrik"},"content":{"rendered":"<div class=\"vc_row wpb_row vc_row-fluid vc_row_visible\"><div class=\"wpb_column vc_column_container vc_col-sm-12 text-left\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div  class=\"text-center  vc_custom_1653863807477\"><div><div class=\"slide-in-container\"><h3 class=\"text-heading-default font-weight-bold el-title_custom_color mb-12\" style=\"\" data-anim-type=\"\" data-anim-delay=\"0\">AS Kalev chocolate factory wastewater anaerobic and aerobic process pretreatment design (10,000 PE) 2006-2008<\/h3><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div data-vc-full-width=\"true\" data-vc-full-width-init=\"false\" class=\"vc_row wpb_row vc_row-fluid vc_row_visible vc_custom_1653168563397 vc_row-has-fill vc_row-o-content-middle vc_row-flex\"><div class=\"wpb_column vc_column_container vc_col-sm-12 text-left\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p><strong>  Customer: AS Kalev Real Estate Company, Orkla Eesti AS<\/strong><\/p>\n<p>At 2005, due to process design changes water consumption in Kalev chocolate factory was reduced.\nThus, wastewater concentrations increased and local WWTP of J\u00fcri could not handle the loads and Kalev chocolate factory had to establish preliminary treatment plant.<\/p>\n<p>At I phase aerobic pre-treatment was established, at second phase extension of WWTP was designed at which anaerobic pre-treatment with biogas use would be integrated to the treatment process.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row-full-width vc_clearfix\"><\/div><div class=\"vc_row wpb_row vc_row-fluid vc_row_visible\"><div class=\"wpb_column vc_column_container vc_col-sm-6 text-left\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p><strong>Wastewater treatment plant<\/strong><\/p>\n<ul>\n<li>Directing industrial wastewater to the WWTP,<\/li>\n<li>Mixing and accumulation tank,<\/li>\n<li>Chemical dosing pumps for neutralization and adding of nutrients,<\/li>\n<li>Activated sludge reactor is used for aerobic treatment,<\/li>\n<li>After aerobic treatment wastewater will be lead to lamella clarifier, where activated sludge settles,<\/li>\n<li>At I phase it is the only biological phase,<\/li>\n<li>At II phase it will be the last biological phase after anaerobic treatment.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Service offered<\/strong><\/p>\n<ul>\n<li>Wastewater studies,<\/li>\n<li>Preliminary design,<\/li>\n<li>Detail project at two phases,<\/li>\n<li>Project management during construction,<\/li>\n<li>Project management,<\/li>\n<li>Start-up<\/li>\n<li>Operating  (since 2008)<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6 text-left\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"d-inline-block\" ><div class=\"text-left d-inline-block  w-100 rounded-0\"  ><img loading=\"lazy\" decoding=\"async\" class=\"card-img2 pix-img-elem rounded-0  h-1002\" style=\"height:auto;\" width=\"2560\" height=\"1707\" srcset=\"https:\/\/aquaconsult.ee\/wp-content\/uploads\/2022\/05\/3.5.-Vaike-scaled.jpg 2560w, https:\/\/aquaconsult.ee\/wp-content\/uploads\/2022\/05\/3.5.-Vaike-300x200.jpg 300w, https:\/\/aquaconsult.ee\/wp-content\/uploads\/2022\/05\/3.5.-Vaike-1024x683.jpg 1024w, https:\/\/aquaconsult.ee\/wp-content\/uploads\/2022\/05\/3.5.-Vaike-768x512.jpg 768w, https:\/\/aquaconsult.ee\/wp-content\/uploads\/2022\/05\/3.5.-Vaike-1536x1024.jpg 1536w, https:\/\/aquaconsult.ee\/wp-content\/uploads\/2022\/05\/3.5.-Vaike-2048x1365.jpg 2048w, https:\/\/aquaconsult.ee\/wp-content\/uploads\/2022\/05\/3.5.-Vaike-16x12.jpg 16w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" src=\"https:\/\/aquaconsult.ee\/wp-content\/uploads\/2022\/05\/3.5.-Vaike-scaled.jpg\" alt=\"\" \/><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"AS Kalev kommivabriku reovee anaeroobsel ja aeroobsel protsessil p\u00f5hineva eelpuhasti projekteerimine (10\u202f000\u202fie) 2006-2008 Tellija AS Kalev Real Estate Company, Orkla Eesti AS 2005. aastal kolis Kalev kommivabriku tootmine Tallinnast Rae valda rajatud uude tootmishoonesse. Uue tehase k\u00e4iku v\u00f5tmisega rakendati mitmeid...","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"_links":{"self":[{"href":"https:\/\/aquaconsult.ee\/en\/wp-json\/wp\/v2\/pages\/13746"}],"collection":[{"href":"https:\/\/aquaconsult.ee\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/aquaconsult.ee\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/aquaconsult.ee\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/aquaconsult.ee\/en\/wp-json\/wp\/v2\/comments?post=13746"}],"version-history":[{"count":4,"href":"https:\/\/aquaconsult.ee\/en\/wp-json\/wp\/v2\/pages\/13746\/revisions"}],"predecessor-version":[{"id":13750,"href":"https:\/\/aquaconsult.ee\/en\/wp-json\/wp\/v2\/pages\/13746\/revisions\/13750"}],"wp:attachment":[{"href":"https:\/\/aquaconsult.ee\/en\/wp-json\/wp\/v2\/media?parent=13746"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}